Showing all 4 results

The muffle furnace is a universal heating equipment, also known as high-temperature electric furnace, box-type electric furnace in China. According to the appearance and shape, muffle furnace can be divided into box furnace, tube furnace and crucible furnace.


Working Principle

BOX FURNACE

Box-type Furnace

Box furnace is a kind of muffle furnace, and its working mode is periodic operation. SX2 series high temperature box furnace uses high-quality resistance wire, silicon carbide rod or silicon molybdenum rod (It depends on customer requirements.) as heating elements; adopts double-layer shell structure and intelligent temperature control system.

The furnace has the advantages of high precision temperature control, balanced temperature field, simple operation, fast temperature rise and fall, low energy consumption.

TUBE FURNACE

Tube-type Furnace

The working principle of SK2 series tube furnace is based on the law of conservation of energy. That is, electric energy is converted into heat energy.

When the electric furnace is working normally, the heating element generates a large amount of heat in the working room and forms heat convection and heat radiation; the insulation material in the working room absorbs and dissipates a small part of the heat and isolates most of the heat; Thus, the temperature in the working room gradually rises to the preset temperature of the heating material.

BOX FURNACE

Atmosphere Furnace

The atmosphere furnace is a special furnace type designed for products that require atmosphere protection. The furnace can be filled with inert gas, nitrogen, or vacuum. So that the workpiece will not produce oxidative decarburization, it is suitable for atmosphere protection sintering and atmosphere reduction in industrial and mining enterprises. The atmosphere furnace is equipped with various valves, flowmeters, pressure gauges and so on. The furnace body has good airtightness; the vacuum degree can reach -0.1MPa; the operation is simple; the loading and unloading is convenient.

VACUUM FURNACE

Vacuum Furnace

The vacuum furnace uses a vacuum system to discharge part of the material in the furnace chamber in the specific space of the furnace chamber, so that the pressure in the furnace chamber is less than a standard atmospheric pressure, and the space in the furnace chamber achieves a vacuum state.

Application

application

Coal quality analysis; it can also be used as a general-purpose ashing furnace;

Thermal processing, cement, building materials industry;

Pharmaceutical industry;

Analytical Chemistry Industry;

Specification

Box-type Furnace

Model

Maximum

Temperature

(℃)

Furnace

Size

(mm)

Input

Power

(V/KW)

SX2-1-12TP

1200℃

100x100x100

220V/1KW

SX2-2-12TP

1200℃

200x150x150

220V/2KW

SX2-6-12TP

1200℃

300x200x200

220V/6KW

SX2-9-12TP

1200℃

400x300x300

220V/9KW

SX2-2-14TP

1400℃

100x100x100

220V/2KW

SX2-4-14TP

1400℃

200x150x150

220V/4KW

SX2-7-14TP

1400℃

300x200x200

220V/7KW

SX2-16-14TP

1400℃

400x300x300

380V/16KW

SX2-2-17TP

1700℃

100x100x100

220V/2KW

SX2-4-17TP

1700℃

200x150x150

220V/4KW

SX2-9-17TP

1700℃

300x200x200

380V/9KW

SX2-16-17TP

1700℃

400x300x300

380V/16KW

 

Tube-type Furnace

Model

Highest temperature(℃)

Chamber size(mm)

Input power/power(V/KW)

SK2-2-14TPA2

1400℃

Φ40x205

220V/2KW

SK2-4-14TPB2

1400℃

Φ60x205

220V/4KW

SK2-5-14TPC2

1400℃

Φ80x205

380V/5KW

SK2-6-14TPD2

1400℃

Φ100x205

380V/6KW

SK2-3-14TPA3

1400℃

Φ40x350

220V/3KW

SK2-5-14TPB3

1400℃

Φ60x350

220V/5KW

SK2-6-14TPC3

1400℃

Φ80x350

380V/6KW

SK2-7-14TPD3

1400℃

Φ100x350

380V/7KW

SK2-4-14TPA4

1400℃

Φ40x440

220V/4KW

SK2-5-14TPB4

1400℃

Φ60x440

220V/5KW

SK2-7-14TPC4

1400℃

Φ80x440

380V/7KW

SK2-8-14TPD4

1400℃

Φ100x440

380V/8KW

Atmosphere Furnace

Item No.

Max. Temperature

Inner Chamber size (mm)  DxWxH

Voltage/Power

(V/KW)

SA2-1-12TP

1200℃

100*100*100

AC 220V/1KW

SA2-2-12TP

1200℃

200*150*150

AC 220V/2KW

SA2-6-12TP

1200℃

300*200*200

AC 220V/6KW

SA2-9-12TP

1200℃

400*300*300

AC 380V/9KW

SA2-2-14TP

1400℃

100*100*100

AC 220V/2KW

SA2-4-14TP

1400℃

200*150*150

AC 220V/4KW

SA2-7-14TP

1400℃

300*200*200

AC 220V/7KW

SA2-16-14TP

1400℃

400*300*300

AC 380V/16KW

SA2-2-17TP

1700℃

100*100*100

AC 220V/2KW

SA2-4-17TP

1700℃

200*150*150

AC 220V/4KW

SA2-9-17TP

1700℃

300*200*200

AC 380V/9KW

SA2-16-17TP

1700℃

400*300*300

AC 380V/16KW

Vacuum Furnace

Model

Heating elements

Size of chamber

(mm)

Vacuum degree(Pa)

SV2

Resistance wire/Silicon carbon rod/

Silicon molybdenum rod/

Molybdenum strip/

Molybdenum rod

 

100x100x100

1-10-6

SV2

Resistance wire/Silicon carbon rod/

Silicon molybdenum rod/

Molybdenum strip/

Molybdenum rod

 

200x150x150

1-10-6

SV2

Resistance wire/Silicon carbon rod/

Silicon molybdenum rod/

Molybdenum strip/

Molybdenum rod

 

300x200x200

1-10-6

Maintenance

Muffle Furnace must be dried when it is used for the first time or again after long-term disuse

Turn off the main power switch after use

The equipment should be placed in a dry and ventilated place without corrosive gas

Check the equipment regularly and repair it in time if it fails.

REQUEST A QUOTE