DLSB series low temperature Cooling Liquid Circulating Pump adds the circulating water pump on the basis of the refrigeration. The new design is elegant and the circulation system is made of stainless steel, with anti-corrosion, anti-rust, anti-cold liquid pollution and other properties.

What are the Types of Chillers?

There are several types of chillers, including the water-cooled chiller, air-cooled chiller, and evaporation cooled chiller. These different kinds of chillers have different characteristics, advantages and disadvantages. Water-cooled systems can offer a high efficiency and environmental impact advantages over air-cooled systems.

How does a Chiller Work?

A chiller consists of the usual evaporator, condenser, compressor, and expansion device set up. The working process of a chiller can be simply described below. A chiller can cool water or oher fluids, which are used to cool equipment. After absorbing heat from what is being cooled, the water or other fluids can go through the chiller. In the chiller, the heat is transferrred from the fluid to the ambient air.

Some Tips on Using a Chiller

1. All operators should read this specification before proceeding;

2. If it is not specified as “explosion-proof” type, this equipment is not suitable in flammable and explosive workplaces.

3. This equipment is not used in places where the environment is rotted seriously;

4. Strong magnetic fields may affect the normal operation of the machine, so the device is not suitable for environments with strong magnetic fields;

5.This equipment allows the working environment temperature range of 5 ° C ~ 30 ° C, humidity ≤ 85%, beyond this range will affect the safety and usage performance of the equipment.

Next, I will introduce the latest Low Temperature Cooling Liquid Circulating Pump:

Picture

Product Name

Product Parameter

DLSB-5/10低温冷却液循环泵
1.Output refrigerating capacity:280-620W
2.Total power:420W
3.Total current:2.1A
DLSB-20/30低温冷却液循环泵
1.Output refrigerating capacity:246-1845W
2.Total power:1350W
3.Total current:7.2A
DLSB-50/30低温冷却液循环泵
1.Output refrigerating capacity:559-4190W
2.Total power:2930W
3.Total current:13.8A
DLSB-100/80低温冷却液循环泵
1.vacuum degree: 0.098Mpa
2.Stirring power:120W1/3
3.heating power:8KW
Note:If the explosion-proof Low Temperature Cooling Liquid Circulating Pump is needed, the price of the non-explosion-proof Low Temperature Cooling Liquid Circulating Pump shall be increased by 1000$.

DLSB-5/10Low Temperature Cooling Liquid Circulating Pump Introduction

1.DLSB-5/10Low Temperature Cooling Liquid Circulating Pump

DLSB-5 series low-temperature cooling liquid circulating pump, also known as low temperature pump, low temperature circulating pump, low temperature cooling water circulating pump, water tank volume is 5L, min no-load temperature is between -15℃~-123℃, best environment temperature is 5℃~25℃.

DLSB低温冷却液循环泵
DLSB Low Temperature Cooling Liquid Circulating Pump

Product Advantages:

1.The circulation system is made of stainless steel and has anti-corrosion and anti-rust functions.

2. Imported air-cooled fully enclosed compressor unit with advanced performance and reliable quality.

3. Digital display constant temperature display, microcomputer temperature control, simple operation.

DLSB-20/30Low Temperature Cooling Liquid Circulating Pump Introduction

2.DLSB-20/30Low Temperature Cooling Liquid Circulating Pump

DLSB-20 series low-temperature cooling liquid circulating pump, also known as low temperature pump, low temperature circulating pump, low temperature cooling water circulating pump, water tank volume is 10L, min no-load temperature is between -15℃~-122℃, best working environment is 5℃~25℃. DLSB-20 series of low-temperature cooling liquid circulating pump is a low temperature liquid refrigerant equipment which takes mechanical forms to refrigerate. It has the function of providing a cryogenic liquid, low temperature water bath. It can be combined with the rotary evaporator, glass reactor, vacuum freezing drying oven, circulating water vacuum pump, magnetic stirrer and other instruments to proceed multi-functional chemical reaction or store drugs under low temperature condition.

20L-30冷水机组
20L-30 chiller

Product Advantages:

1.The circulation system is made of stainless steel and has anti-corrosion and anti-rust functions.

2. Imported air-cooled fully enclosed compressor unit with advanced performance and reliable quality.

3. Digital display constant temperature display, microcomputer temperature control, simple operation.

DLSB-50/30Low Temperature Cooling Liquid Circulating Pump Introduction

3.DLSB-50/30Low Temperature Cooling Liquid Circulating Pump

DLSB-50 series low-temperature cooling liquid circulating pump, also known as low temperature pump, low temperature circulating pump, low temperature cooling water circulating pump, water tank volume is 50L, min no-load temperature is between -23℃~-120℃, best working environment is -10℃~-120℃. The circulating water pump is added on the basis of refrigeration, which enables the cooled liquid to go through the pipeline for external and internal circulation. It can provide cryogenic liquid for external equipment such as double-layer glass reactor, organic synthesis device and rotary evaporator.It can be combined with the rotary evaporator, glass reactor, vacuum freezing drying oven, circulating water vacuum pump, magnetic stirrer and other instruments to proceed multi-functional chemical reaction or store drugs under low temperature condition.

20L-30冷水机组

Product Advantages:

1.The circulation system is made of stainless steel and has anti-corrosion and anti-rust functions.

2. Imported air-cooled fully enclosed compressor unit with advanced performance and reliable quality

3. Digital display constant temperature display, microcomputer temperature control, simple operation

Laboratory Low temperature cooling liquid water circulating pump DLSB 5L/-10℃ test machine:

Matching Products

Picture

Product Name

Product Description

  Rotary evaporator is mainly used for continuous distillation of a large number of volatile solvents under negative pressure conditions.In particular, the concentration of the extract and the distillation of the receiving liquid in the chromatographic separation can separate and purify the reaction product.
S212-2L Glass reactor
Glass reactor plays the role of reaction material in laboratory instruments and is often used in modern fine chemical industry, biopharmaceutical industry, scientific research experiment and other industries.

  The device has simple structure, small floor space, high evaporation and recycling efficiency.

Mainly used in fractionation process.


Troubleshooting:

1 The whole machine has no electricity No power supply Check the power supply
Circuit breaker protection Reset circuit breaker
Fuse burn Replace fuse
Power line off Tighten the power line
Wrong phase sequence of power supply Adjust the position of two fire wires at will
2 No temperature display No temperature display Turn on the power switch
Display board line off Plug in the sensor socket
Water splashed on the circuit board Dry or sun dry before starting
3 Display on the  □□□□or EO Sensor break Plug in the sensor socket
Sensor short circuit Replace the sensor
4 Display on the  □□□□or EO Sensor short circuit Replace the sensor
5 Display does not match the actual Sensor off Reinstall and tighten
6 Temperature control disorder Voltage instability Stabilize the voltage before starting up
The temperature control circuit is broken Replace the temperature control circuit
7 No cooling or slow cooling System leakage Please have it repaired by a professional
8 The machine stops when the temperature does not reach the set value The temperature control circuit is broken Replace the temperature control circuit
Compressor overheating protection Improve ventilation and start after cooling
9 No exhaust air Fan power cord is not in good contact Connect the power wire
Fan stuck Adjust fan position
The wind leaf deformation Replace the new fan
Fan burn out Replace the new fan
10 The compressor is not working but there is a click Starting capacitor breakdown Replace capacitors of the same type
Compressor is bad Replace compressor of the same type
11 No external loop Power line off Tighten the power line
The water inlet is blocked Remove the blockage
Adjustment valve is not open Open the adjustment valve
There is ice blocking in the circulating pump Shut down and thaw
12 Fuse burn Start capacitor burnout Replace capacitors of the same type
There is a short circuit Check each line

[title text=”Related Products” tag_name=”h2″ color=”rgb(119, 199, 239)”]

[ux_products columns=”3″ ids=”2868,3030,24120″]

[title text=”Related Posts” tag_name=”h2″ color=”rgb(119, 199, 239)”]

[blog_posts style=”vertical” columns=”3″ columns__md=”1″ depth=”2″ slider_nav_style=”simple” slider_nav_position=”outside” ids=”6716,6656,6474″ image_height=”89%” image_width=”43″]

Leave a Reply

Your email address will not be published. Required fields are marked *