DLSB-200/40 Low Temperature Coolant Circulation Pump(Chiller)

Contact us for a free quote

Description

The low temperature coolant circulation pump adopts the air-cooled fully enclosed compressor unit for cooling and the microcomputer intelligent control system. It can provide low-temperature circulating cooling water (liquid) or low temperature thermostatic water (liquid) to cool equipment or keep equipment at a constant temperature, such as rotary evaporator, fermentation tank, electron microscope, low temperature chemical reactor, electron spectrometer, mass spectrometer, density meter, freeze dryer, vacuum coating apparatus, reactor and other equipment.

low temperature coolant circulation pump(chiller)
low temperature coolant circulation pump(chiller)

Product Features

1.The system features compact structure, less land occupation, high cooling and heating efficiency.

2.The large size color touch screen can clearly display the real-time temperature change during the process engineering.

3.The circulating pump and compressor can work continuously at low temperature, control heat dissipation and protect the system from damage.

4.The overhead design of the fan can meet more heat dissipation requirements.

5.It is convenient and quick to maintain the equipment with the door and window type opening and closing design.

6.The circulating pump adopts the shield pump to solve the leakage problem of the circulating pump.

Product Parameters

Product NameChiller
Product ModelDLSB 200L-40℃
Non-Loaded Minimum Temperature-40℃
Temperature Fluctuation±2℃
RefrigerantR404
Cooling Capacity (W)390~22600
Total Power (W)8640W
Current (A)40
Circulating Pump Power (w)280
Circulating Pump Flow (L/min)35
Circulating Pump Head (M)18
External circulation interface (mm)19

Product Details

The large size color touch screen can clearly display the real-time temperature change during the process engineering.

color touch screen
color touch screen

It is convenient and quick to maintain the equipment with the door and window type opening and closing design.

the door and window type
the door and window

The overhead design of the fan can meet more heat dissipation requirements.

The overhead design of the fan
The overhead design of the fan

It is more accurate to judge the machine faults with the display of dual pressure gauges at high and low pressure ends of the compressor.

dual pressure gauges
dual pressure gauges

Troubleshooting for Not Working of Chiller

1.Firstly, pay attention to whether the boot order is correct;

  •   Add proper secondary refrigerant;
  •   Connect the power cord to the special power supply;
  •   Close the circuit breaker;
  •   Press the “Power” button;
  •   Turn on the circulating switch;
  •   Turn on the cooling switch;
  •   Turn on the cool storage device; (The fifth and sixth points are important.)

2.Check whether the secondary refrigerant is correct. More than 97% of the ethanol solution should be used in most cases. (Don’t use motor vehicle antifreeze fluid as the secondary refrigerant, which will damage the service life of the pump after a long time.)

3.The injection of the secondary refrigerant should be in line with the coil pipe in the reservoir, not too much or too little. (The too little secondary refrigerant will influence the cooling effect of the pump.)

4.Confirm if there is fluorine in the compressor: there is a pressure gauge on the equipment that is equal or more than 30L, so directly see the value of the pressure gauge. Or ask professional personnel to judge whether it is normal by taking a picture. (Normally, the pressure gauge should be in the range of 0.8-0.9MPa at room temperature before starting the pump; For double compressors, the pressure gauge of the primary compressor should be in the range of 0.8-0.9MPa at room temperature, and that of the secondary should be in the range of 1.4-1.9MPa at room temperature.) The pressure gauge should display in the range of 0-0.25MPa during the normal starting state of the pump. (The double compressors are same as it.)

5.If there is sufficientfluorine in the compressor: It can be defined as fluorine deficiency if the pressure gauge value of the compressor at room temperature is lower than 6MPa when the pump is shut down. But the value should be at least 0.2MPa. (Too low pressure will make the foam water be drawn into the compressor, damaging the compressor.) It is necessary to check whether there is any leakage in the equipment firstly at this moment. The specific method is as follows: apply soapy water, detergent, and other foaming liquids to the welding place of copper pipes inside the compressor, and observe whether there are bubbles at this time. It will prove that there is leakage in the pipeline if bubbles appear. Ask professional personnel to fix the leakage. Inject the refrigerant according to the types and methods provided by our company after fixing, and then restart the equipment.

6.Don’t add any secondary refrigerant into the cool storage device when the temperature of the secondary refrigerant is lowered to the setting value by the pump.

7.It is required to clean the condenser when the pump works slowly or badly. (Clean the condenser of the pump at least once a week to avoid the blockage of the condenser and prevent the compressor from burning down due to the heat can’t be removed.)

Precautions for Use

1.Check whether the inlet and outlet valves of the refrigeration equipment can be normally opened and the pressure is in the normal range.

2.Check whether the power supply of each device is turned on.

3.Put the secondary refrigerant of more than 97% ethanol into the reservoir before using a low temperature coolant circulation pump. The liquid level of the medium should submerge the coil pipes inside the reservoir.

4.Check the power supply: The power of the power supply should be greater than the total power of the equipment, and the power supply should be well grounded.

5.The equipment should be placed in a dry and ventilated place. There is no obstacle around it within 500mm.

6.Pay attention to the liquid level in the reservoir. Add the secondary refrigerant in time when the liquid level is too low.

7.The temperature of the inlet and outlet pipes is relatively low during the working time, so don’t touch them in case of frostbite.

8.All switches should be turned off and the power supply should be cut after use.

9.Clean the condenser regularly to prevent the use efficiency of the product being reduced because of too much dust.

certification
certification

packing and delivery
packing and delivery

Pre-Sale Service

  1. Provide 24-hour technical consultation and reply;
  2. Provide professional quotation information;
  3. Provide detailed product performance specification;
  4. According to product’s using condition, technicians will offer rationalization proposals to assist clients to select proper product types;
  5. Provide other corollary equipment according to client requirements.

In-Sale Service

  1. With supervision from the source of products, the qualified rate of raw materials entering the factory can reach 100%;
  2. Whole manufacturing process are in strict accordance with promised procedure requirements, product qualified rate can reach100%;
  3. Provide product’s inspection record of key junctures to customers;
  4. Provide production schedule photos to customers at regular intervals;
  5. Package and transport of products are in strictaccordance with the export standard;
  6. Provide transportation schedule information to clients timely.

After-Sale Service

  1. Provide targeted installation video;
  2. Under the premise of correct installation, normal maintenance and using, we guarantee one-year warranty period;
  3. When warranty period has expired, our sold products enjoys lifetime guarantee repair, we only charge cost price for changing product’s standard component and sealing component;
  4. During installation and adjustment period, our after-sale service staff will communicate with customers frequently to know product’s running state in time. Assist customers to install and adjust products until customers are satisfied;
  5. If product has malfunction during operation period, we’ll offer you satisfied answer in time. We’ll reply you within 1 hour and provide solution or send staff to spot within 24 hours after receiving maintenance notification;
  6. Lifelong free technical support. Conduct satisfaction survey and inquiry equipment running condition to clients by telephone or e-mail semiannually from the first day of equipment running, put on records of acquired information;
  7. Provide assistance in solving problems such as equipment damage in the transport.

Ready to Query? Get a quote now!

Contact us for a free quote

Additional information

Voltage:

220V/380V/415V

Certification:

ISO9001

Application Industries

Chemical Industry

Material:

Stainless Steel / Titanium evaporator

Reviews

There are no reviews yet.

Be the first to review “DLSB-200/40 Low Temperature Coolant Circulation Pump(Chiller)”

Your email address will not be published. Required fields are marked *